0
Fire & Emergency

Severe Weather Response

Severe weather monitoring and response for lightning, high wind, tornado and flooding events.

Rev 02 Updated Apr 19, 2026

What This Procedure Covers

  1. Prepare before conditions deteriorate

    Use for site preparation and worker protection during thunderstorms, tornadoes, high winds and flooding. Complete for the actual site and local warning service. Heat, cold and specialist recovery work require their separate task assessments.

    Make the plan usable before the shift starts: Assign someone to monitor official forecasts and alerts throughout exposed work. Brief shelter locations, signals and routes with every crew, including remote workers. Check communications and a backup alert method; a phone app alone can fail through poor coverage or loss of power.

  2. Define triggers and move people early

    Use forecast lead time to stop exposed work, secure equipment safely and reach shelter. A watch calls for readiness; a warning calls for the protective action specified by the local authority. Do not wait for an alert when dangerous conditions are already apparent.

    Protect people before equipment: Confirm shelters are accessible and large enough for everyone. Include travel time from roofs, work platforms and remote work areas. Secure materials before the storm arrives; do not send workers back into dangerous conditions to retrieve tools, lower equipment or finish a lift. Account for workers, contractors and visitors at shelter. Report anyone missing and their last known location to the emergency coordinator or emergency services. Do not send an untrained search party into the hazard. Keep instructions available during power or network loss.

  3. Lightning: reach suitable shelter

    Stop outdoor exposure and move to shelter immediately when thunder is heard. Act earlier when the forecast, visible lightning or site detection system indicates an approaching threat. Do not wait to measure a flash-to-thunder interval or for rain to begin.

    There is no safe outdoor lightning position: Use a substantial building or an enclosed metal-topped vehicle with windows closed. Tents, open-sided shelters, trees and open machinery cabs are unsuitable. Rainwear and footwear are not lightning protection. Do not use a crouch as a substitute for getting inside; never lie flat outdoors. Inside, avoid wired electrical equipment, plumbing, windows and doors. Remain sheltered for at least 30 minutes after the last thunder; restart the waiting period for new thunder. The elapsed time alone does not clear other hazards or override a longer site restriction.

  4. High wind, hail and tornadoes

    Record operating and securing limits for each crane, lift and temporary structure. Use the equipment instructions, configuration, load characteristics and site assessment. There is no single wind speed that makes every operation safe; account for gusts and conditions at working height.

    Lightning shelter is not automatically tornado shelter: For a tornado warning or approaching tornado, go promptly to the designated sturdy building shelter: a safe room, basement or protected interior area on the lowest floor away from windows. Protect your head and neck. Vehicles, trailers, tents and sheds are unsuitable planned tornado shelters. Plan early movement where the normal worksite has no suitable building. Do not shelter under an overpass. A ditch is not a planned shelter and may flood. Follow local emergency instructions; do not leave a sound shelter to chase the storm or attempt to outrun it.

  5. Flooding: leave threatened areas

    Monitor upstream conditions, low ground, drainage paths, excavation edges and evacuation routes. Move people to the designated safer area before routes become impassable. Follow evacuation orders; do not delay departure to move equipment.

    Do not enter floodwater to test whether it is safe: Do not walk or drive through floodwater or go around road-closure barriers. Water can conceal washed-out surfaces, energized equipment, contamination and strong currents. Keep away from downed lines and anything touching them; report hazards to the utility and emergency coordinator. Do not touch or energize water-damaged electrical equipment. Utility restoration, spill cleanup and water rescue require appropriately trained and equipped personnel. A general site supervisor or an improvised water test cannot authorize electrical safety or specialist recovery work.

  6. Inspect, authorize and record restart

    Keep affected areas closed until the warning restrictions and site hazards have been assessed. Obtain competent inspections for excavations, access, temporary works and equipment, and qualified assessment of damaged structures or utilities. Record restrictions and brief crews before restarting.

Reference guidance: NWS Lightning Tips, Lightning Crouch, Tornado During and flood safety; OSHA crane operation 1926.1417 and Flood Response; NIOSH hurricane/flood worker guidance. Apply local emergency instructions and equipment limits.

Download the Full PDF Template

Get the complete Severe Weather Response document as a fillable PDF, part of the Safe Work Procedures Template Pack.