Arc Flash Protection
Arc flash hazard assessment, equipment labeling, PPE selection and safe work practices.
Scope and Purpose
This procedure sets out how the company assesses arc flash hazards, labels equipment, selects and cares for arc-rated PPE, and how a crew protects itself when it opens, operates, tests or works on electrical equipment that is or may be energized.
It applies to switchgear, switchboards, panelboards, motor control centres, disconnects, transformers, VFDs and control panels at all company work sites and client sites.
Hazard Identification
- Thermal burns from arc flash
- Clothing ignition and melting
- Arc blast: pressure, flying parts, molten metal
- Eye injury from intense light
- Hearing damage from blast
- Toxic smoke and vaporized metal
- Fire in the room
- Wrong or out-of-date label
- Degraded PPE
- Electric shock while working inside the boundary
Required PPE
- Arc-rated shirt and pants, or arc-rated coverall, with arc rating at or above the label value. Outer layer must be arc-rated.
- Arc-rated face shield with arc-rated balaclava, or arc flash suit hood, at or above the label value.
- Safety glasses under the face shield or hood.
- Nonconductive, electrical-rated hard hat (look for the electrical class marking, Class E). Use an arc-rated hood liner or hood as the label requires.
- Hand protection: rubber insulating gloves with leather protectors (rated for the voltage, see SWP-052). Where no shock hazard exists, heavy-duty leather gloves are allowed only if the study or label says so.
- Hearing protection (inserts) whenever inside the arc flash boundary.
- Leather work boots.
- Underlayers and anything worn under arc-rated clothing must be non-melting natural fibre or arc-rated. No polyester, nylon, acetate, rayon, polypropylene, or blends.
- No exposed metal (zips, jewelry, metal-frame glasses) unless covered.
Key Procedure Steps
Program (manager / engineer)
- Get an arc flash study for each piece of equipment that may be opened, operated or worked on while energized.
- Label each piece of equipment with at least: nominal voltage, incident energy or required PPE, working distance, arc flash boundary, and the date of the study.
- Update the study and labels when the system changes (new or changed transformer, utility supply, feeder, breaker or fuse sizes, or protective settings).
- Where the study shows no available PPE is adequate, mark the equipment "No energized work" and use de-energized procedures only.
Task (crew)
- Check whether the task can be done de-energized.
- Read the label.
- Pick PPE at or above the label value.
- Set barricades at the arc flash boundary.
- Put on all PPE outside the boundary.
- Stand to the side of the door or cover.
- Do the task using the steps in SWP-052.
- Close all doors and covers before leaving the boundary.
- Remove PPE outside the boundary.
- Report any label problems or equipment damage to the supervisor.
PPE care
- Inspect arc-rated clothing before each use for holes, tears, contamination (oil, grease, flammable liquids), and melted or burnt areas.
- Launder only as the manufacturer instructs.
- Any garment exposed to an arc event is removed from service.
Each step is shortened to its first sentence. The full procedure, with every condition, checklist and sign-off field, is in the PDF.
Training Requirements
- Qualified worker: Qualified person training (see SWP-052).
- Supervisor: Label and study interpretation; when to refuse energized work; barricade setup.
- Unqualified workers who work near electrical equipment: Arc flash awareness: what the label and barricades mean, stay outside, report damage.
- PPE wearers (all): Fit and use of the specific PPE issued (Canada COHSR 12.05(1)(b) fitting by a qualified person).
Regulatory References
- 29 CFR 1910.132(d) PPE hazard assessment and certification
- 29 CFR 1910.335(a) Electrical protective equipment, head and face protection
- 29 CFR 1910.137 Electrical protective equipment
- 29 CFR 1910.269(l)(8) Protection from flames and electric arcs (power generation, transmission and distribution only)
- 29 CFR 1926.95, 1926.97; 1926.960(g) (construction power T&D only)
- Canada Labour Code Part II
- Canada Occupational Health and Safety Regulations SOR/86-304, Part VIII Electrical Safety; Part XII Protection Equipment (ss.12.03 to 12.05)
- Provinces and territories have their own OHS regulations.
Download the Full PDF Template
Get the complete Arc Flash Protection document as a fillable PDF, part of the Safe Work Procedures Template Pack.
Get This SWP + 4 More Free
Choose from 112 procedures. No credit card, no commitment.
Pick Your 5 Free SWPsWant Digital Sign-Off for Your SWPs?
Make Safety Easy lets your crew acknowledge procedures on any device. Track who read what, when. No more lost paper forms.
Start Your Free Trial