0
Environmental & Hazmat

Lead Paint Removal

Lead-based paint removal procedures with exposure controls, PPE and clearance testing.

Revision 2.1 Updated Apr 19, 2026

Scope and Purpose

This procedure sets out how to remove, strip or disturb paint and coatings that contain lead, and how to cut or weld lead-coated steel, without workers breathing or swallowing lead dust or fume or carrying it home, and without spreading it to occupants or the ground.

Any paint or coating is treated as containing lead until it is tested. A test result below the "lead-based paint" level (1.0 mg/cm2 or 0.5% by weight) does not mean the work is safe. The OSHA lead standard applies to any work where a worker may be exposed to lead, at any lead content. Only an exposure assessment tells you the exposure.

Hazard Identification

  • Manual demolition (e.g. drywall), manual scraping, manual sanding, heat gun use, power tool cleaning with dust collection; spray painting with lead paint; any other task you have reason to believe is above the PEL
  • Lead-containing mortar; lead burning; rivet busting; power tool cleaning without dust collection; clean-up where dry expendable abrasives are used; moving or removing abrasive blasting enclosures
  • Abrasive blasting; welding; cutting; torch burning
  • Hazard
  • Breathing lead dust from scraping, sanding, power tools
  • Lead fume from heat, cutting, welding, torch burning on coated steel
  • Open-flame burning or high-temperature heat guns
  • Swallowing lead from hands, face, food, drink, tobacco
  • Lead carried home on clothes, shoes, tools, vehicles
  • Dust and debris escaping the work area
  • Chemical strippers (skin burns, vapours, flammability)
  • Respirator not suited, not fitted, or not worn
  • Heat stress in suits, respirators and containment
  • Falls from ladders, scaffolds, bridges, structures
  • Electric shock (wet methods, power tools, HEPA units)
  • Noise and vibration (needle guns, grinders, blasting)
  • Hazardous waste mishandled

Required PPE

  • Selected by assigned protection factor for the task (Section 4 table) or the measured exposure.
  • HEPA filters on all air-purifying respirators and PAPRs.
  • A full facepiece instead of a half-mask where lead aerosols cause eye or skin irritation.
  • A PAPR whenever a worker asks for one and it gives enough protection.
  • No filtering facepiece (dust mask) respirators (company rule).
  • Fit tested before first use, on any change of facepiece, and at least annually (1910.134(f)(2)).
  • Coveralls or similar full-body work clothing.
  • Gloves; chemical-resistant outer gloves when using strippers.
  • Hat or hood; shoes or disposable shoe covers.
  • Face shield, vented goggles or other eye protection.
  • Hard hat where there is overhead work; hearing protection where the noise assessment requires it; fall protection per SWP-004.
  • Clean, dry clothing provided at least weekly, and daily for workers above 200 ug/m3 (8-hour average, without respirators).

Key Procedure Steps

Plan and assess

  1. Test the coatings (lab paint chip analysis or XRF), or treat them as containing lead.
  2. Check the building type.
  3. Write or update the compliance program: each lead-emitting activity (equipment, materials, controls, crew size, duties, procedures); how compliance is achieved; air monitoring data; the schedule; the work practice and hygiene program; arrangements with other contractors.
  4. Match each task to its interim-protection group (Section 4).

Set up

  1. Post signs at each work area: "DANGER / LEAD WORK AREA / MAY DAMAGE FERTILITY OR THE UNBORN CHILD / CAUSES DAMAGE TO THE CENTRAL NERVOUS SYSTEM / DO NOT EAT, DRINK OR SMOKE IN THIS AREA".
  2. Interior: remove or cover objects; close and seal windows, doors and HVAC openings; cover the floor with taped-down sheeting at least 6 ft beyond the work, or further to contain the dust.
  3. Exterior: cover the ground at least 10 ft beyond the work, or further to catch debris; close nearby windows and doors; use vertical containment within 10 ft of a property line, in wind, or on bridges and elevated steel.
  4. Set up the change area, hand-washing station, clean eating area and closed waste containers.
  5. Check shrouds and HEPA vacuums before use.

Remove

  1. Use the lowest-dust method that works: component removal, chemical stripping, wet scraping, wet sanding, then shrouded power tools with HEPA extraction.
  2. Keep surfaces misted for scraping and sanding.
  3. Power tools: operate so no visible dust leaves the shroud.
  4. Heat guns: below 1,100 F only.
  5. Chemical strippers: methylene chloride-free; apply and wait per the manufacturer; scrape the softened coating into containers; neutralize and clean per the SDS.
  6. Hot work on coated steel: strip the coating at least 4 in back from the heat point, and far enough that the unstripped metal does not heat up.
  7. Collect chips and debris as you go.

During the work

  1. Wear the respirator for your task the whole time you are in the work area.
  2. Do not eat, drink, use tobacco or apply cosmetics in the work area.
  3. Clean up during the shift: HEPA vacuum or wet methods.
  4. Competent person inspects the controls and work practices often and regularly.

End of shift

  1. HEPA-vacuum gross dust off PPE. Remove protective clothing only in the change area.
  2. Shower where showers are provided (required where feasible above the PEL).

Final clean-up and clearance

  1. Mist and fold sheeting inward, bag it, and HEPA-vacuum and wet-wipe all surfaces in the work area (walls from the top down, then floors).
  2. Competent person or certified renovator checks visually: no dust, debris or paint chips left.
  3. RRP jobs: the certified renovator does the cleaning verification with the EPA card; re-clean any surface that fails, as the rule sets out.
  4. EPA abatement jobs: a certified inspector or risk assessor does the visual inspection and dust-lead clearance testing, at least 1 hour after final clean-up.
  5. Other jobs (commercial, industrial, steel structures): clear to the project specification and your jurisdiction.

Waste

  1. Collect chips, dust, sheeting, filters, wash water residue and disposable PPE in closed, labelled containers.
  2. Have representative waste tested by TCLP. Waste with 5.0 mg/L lead or more in the extract is hazardous waste (D008).

Each step is shortened to its first sentence. The full procedure, with every condition, checklist and sign-off field, is in the PDF.

Training Requirements

  • Worker on an interim-protection task before the assessment is done (US): Hazard communication, respirator use and general safety training (1926.62(d)(2)(v)(F)).
  • Worker exposed at or above the action level on any day (US): Before job assignment: the lead standard and appendices; the operations that could expose them above the action level; respirators; medical surveillance and medical removal, including reproductive effects and extra precautions for pregnancy; engineering controls and work practices for their job; the compliance program; that chelating agents are not to be used except under a physician; their right to records (1926.62(l)).
  • Competent person (US) / qualified person (Canada federal): Able to identify existing and predictable lead hazards, select controls and order corrections.
  • Certified renovator (US RRP jobs): Accredited renovator course, at least 8 hours with 2 hours hands-on (40 CFR 745.225(c)(6)(vi)).
  • Lead abatement worker / supervisor (US target housing and child-occupied facilities): EPA or state certification.
  • Canada federal: anyone handling or exposed to lead: The employer's education and training program on the hazardous substance, the hazard information and the qualified person's observations (COHSR 10.14).
  • All respirator users: Respirator training and fit test (1910.134).

Regulatory References

  • US OSHA 29 CFR 1926.62, Lead (construction), including (b) definitions, (c) PEL, (d) exposure assessment and interim protection, (e) compliance program, (f) respirators, (g) protective clothing, (h) housekeeping, (i) hygiene, (j) medical surveillance, (k) medical removal protection, (l) training, (m) signs, (n) records.
  • US OSHA 29 CFR 1926.354, Welding, cutting and heating in way of preservative coatings.
  • US OSHA 29 CFR 1910.134, Respiratory protection (Table 1 assigned protection factors; fit testing; training).
  • US OSHA 29 CFR 1904.39, Reporting fatalities, hospitalizations, amputations and losses of an eye.
  • US EPA 40 CFR 745 Subpart E (Renovation, Repair and Painting: 745.82, 745.83, 745.85, 745.90) and Subpart L (lead-based paint activities: 745.223, 745.225, 745.226, 745.227); 745.103 definitions.
  • US EPA 40 CFR 261.24, Toxicity characteristic (D008 lead).
  • Canada: COHSR SOR/86-304, Part X ss. 10.4 to 10.6, 10.14, 10.19; Part XII s. 12.13; Part XV s. 15.5 (federally regulated workplaces).
  • 29 CFR 1910.1025 (general industry lead), HUD Guidelines for lead-based paint in housing, CSA Z94.4. Named only.
  • Provincial lead and waste regulations and US state lead programs. Use the ones for your location.

Download the Full PDF Template

Get the complete Lead Paint Removal document as a fillable PDF, part of the Safe Work Procedures Template Pack.

Get Template Pack

Get This SWP + 4 More Free

Choose from 112 procedures. No credit card, no commitment.

Pick Your 5 Free SWPs

Want Digital Sign-Off for Your SWPs?

Make Safety Easy lets your crew acknowledge procedures on any device. Track who read what, when. No more lost paper forms.

Start Your Free Trial