- Establish the work limits and authorizations
For trained crews verifying and exposing buried utilities before ground disturbance. Complete with the local one-call requirements, facility-owner instructions and excavation plan. This record does not authorize utility repair, energized work or entry into an excavation.
One-call notification is only part of the investigation: Confirm all required responses and reconcile them with the actual site marks before starting. Arrange investigation of private or non-member facilities. Review records and surface clues; no paint, an old drawing or an assumed abandoned line does not prove the area is clear.
- Reconcile marks and select exposure points
Preserve markings and keep the current ticket and owner instructions with the crew. Stop affected work for missing, unclear or conflicting marks, an unexpected facility or a change beyond the ticket scope. Resolve discrepancies and obtain renewed information when required.
Locate marks do not establish exact depth: Use the jurisdiction-specific tolerance zone and owner restrictions; do not substitute a generic distance measured from a paint line. Determine actual position using an approved exposure method before approaching with excavation equipment. Do not assume a utility stays at one depth or runs straight between exposures. Mechanical excavation restrictions vary. Follow the applicable rule and facility-owner method, including supervision and standby requirements. A marked boundary is not permission to dig blindly up to it. Continue looking for additional facilities even after the expected line is located.
- Approve the exposure method and site controls
Select hand or vacuum excavation only after checking the utility material, condition and owner requirements. Use trained operators and equipment capable of meeting the approved settings. Neither air nor water excavation is automatically safe around every cable, pipe or coating.
Non-destructive does not mean damage-proof: Use the equipment and facility-owner instructions to set and verify operating limits. Do not improvise pressure or nozzle settings or assume switching from water to air removes the hazard. Stop if the equipment cannot meet the required limits. Inspect tools and hoses before use. Keep people clear of jets, suction inlets and moving equipment. Use suitable hand tools cautiously; an insulated handle or rubber glove is not permission to contact an energized cable. Apply the separate excavation assessment for collapse, water, atmosphere, access and edge protection before any entry.
- Expose, identify and record
Expose using the approved method without striking, levering or dragging against the facility. Stop and obtain owner direction if identity, condition or location differs from expectations. Keep the exposure protected while measurements and photographs are taken.
Record a repeatable position, not just a depth number: Reference a fixed datum and record the surface level, depth, offset and direction at the exposure. Identify the measurement point on the facility, the units and the drawing/photo reference. Record limitations where the full configuration is not visible; do not label an uncertain identification as confirmed. One pothole does not establish the entire route or clear all adjacent ground. Use the required exposures at crossings and changes in alignment, and extend verification as work progresses. Have the responsible supervisor brief the excavation crew on the verified limits and remaining uncertainty.
- Protect exposed services and respond to damage
Provide owner-approved support and protection while the excavation remains open. Protect holes from falls, traffic and unintended loading. Do not hang hoses or equipment from a service, move it, or install an improvised support that could damage it.
Report contact even when there is no visible leak: Stop affected work and report suspected contact or damage promptly, including coating damage, dents, scraped insulation and disturbed protective components. Do not conceal, repair or backfill damage without owner assessment and clearance. Record notifications and the written direction received. For a gas or hazardous-material release, evacuate and call emergency services and the utility from safety; avoid ignition sources. Do not investigate or repair the leak. Suspected electrical contact needs the electrical-contact plan: keep others away and remain on contacted equipment unless an immediate life threat forces escape. Obtain utility clearance before approach or restart.
- Backfill, hand over and close the record
Obtain required owner inspection before covering the facility. Use approved bedding, backfill and compaction methods without moving or loading the utility beyond its permitted limits. Restore the surface and markings; retain the verification record for subsequent work.
Reference guidance: OSHA 1926.651(b) and October 23, 2003 hydro-vacuum interpretation; Sunshine 811 excavator and buried-facility guidance; Dig Safe handbook. Apply the actual jurisdiction and utility-owner requirements, not another region's distances.
Download the Full PDF Template
Get the complete Utility Locate and Expose document as a fillable PDF, part of the Safe Work Procedures Template Pack.
Get This SWP + 4 More Free
Choose from 112 procedures. No credit card, no commitment.
Pick Your 5 Free SWPsWant Digital Sign-Off for Your SWPs?
Make Safety Easy lets your crew acknowledge procedures on any device. Track who read what, when. No more lost paper forms.
Start Your Free Trial