Vacuum Truck / Hydrovac
Vacuum truck and hydrovac operation with high-pressure injection injury prevention and utility exposure.
What This Procedure Covers
- Confirm the task and equipment suitability
For trained crews using vacuum or hydrovac equipment within its rated application. Complete with the exact truck manual and material assessment. Hazardous-waste recovery, flammable products, tank entry and specialist cleaning need separate authorization and procedures.
Do not collect unknown or incompatible material: Confirm that the unit, hoses, tank and collection method are suitable for the material, temperature and hazards. Check previous contents and cleaning records before loading. Do not assume a general hydrovac can recover flammable liquids or combustible dust. Stop for unexpected vapours, reactions or unidentified waste.
- Inspect, position and establish the work zone
Inspect the chassis, boom, tank, hoses, connections, guards and required inspection records. Function-check controls and safety devices under the manufacturer method. Plan access, vehicle movement and stable support for the truck at its expected loaded weight.
Make emergency controls usable by the crew: Verify the required vacuum relief and emergency controls are fitted, functional and accessible from the working position. Agree a stop signal and assign crew responsibilities. Follow the manufacturer staffing requirement; do not leave the hose operator without the required support. Size the exclusion area for hose movement, spray, falling material, traffic and the excavation rather than using a fixed ten-foot rule. Keep hoses out of pedestrian routes or protect crossings. Control engine exhaust and blower discharge so they do not expose workers or enter occupied spaces.
- Protect people from suction and pressure
Keep the suction inlet away from the body and maintain the specified operating arrangement. Do not use a hand, foot or other body part to block or check suction. Shut off and make the system safe before connecting, changing or clearing a hose or attachment.
Do not bypass the operator control: Keep jetting trigger and safety controls functional; never tie or wedge them open. Point the wand away from people and maintain stable footing. Stop for a damaged hose, leaking connection or uncontrolled movement. Do not search for a pressurized leak with your hand or improvise a repair. Treat suspected injection or vacuum injury as an emergency even if the visible wound looks small. Stop the hazardous action using the trained emergency method, call for urgent medical help and explain the pressure or suction mechanism and material involved. Do not delay assessment to see whether pain develops.
- Excavate only to the approved utility method
Use the utility-locate and exposure plan before ground disturbance. Verify facility-owner restrictions and the correct nozzle, pressure, temperature and standoff for the equipment and service. A generic pressure or distance is not an approved setting.
Hydrovac can damage services and destabilize ground: Follow the approved exposure method and stop for unexpected services, damaged coatings, loss of soil or unstable edges. Do not enter the excavation as part of this routine. Any proposed entry needs a separate assessment and protection plan; not every hydrovac hole has the same confined-space classification. Monitor capacity and legal vehicle loading; tank volume alone does not establish a safe payload. Keep the boom within its intended use and clear of overhead hazards. Do not use the suction system for rescue or the boom as an improvised lifting crane.
- Unload and clean under the unit instructions
Use an authorized disposal location with firm, level support, adequate overhead clearance and a controlled unloading area. Verify material acceptance. Follow the model-specific pressure-release, door and body sequence; keep everyone clear of discharge and pinch zones.
Keep clear of raised bodies and doors: Do not go beneath a raised loaded body. Servicing beneath an empty raised body or near an open door requires the specified mechanical supports and safe-state procedure. Do not rely on hydraulics alone or loosen a closure to test for trapped pressure. Stop unloading if material hangs up or the truck becomes unstable. Do not enter the debris tank to clean it under this procedure. Tank entry requires its own confined-space assessment, isolation, entry authorization and rescue arrangements. Collect washwater and residues through the approved disposal route; prevent releases to drains or surrounding ground.
- Prepare for transport and hand over
Confirm the body and door are secured, boom and hoses stowed, tools retained and operating systems in their travel state. Check the route and personnel before moving. Retain waste records, equipment faults and utility-exposure documentation with the job.
Reference guidance: Vactor / Federal Signal safety manual; HSE high-pressure injection hazards; Water Jetting Association injury guidance; OSHA utility-exposure interpretation. Complete with the exact model instructions, utility requirements and local waste rules.
Download the Full PDF Template
Get the complete Vacuum Truck / Hydrovac document as a fillable PDF, part of the Safe Work Procedures Template Pack.
Get This SWP + 4 More Free
Choose from 112 procedures. No credit card, no commitment.
Pick Your 5 Free SWPsWant Digital Sign-Off for Your SWPs?
Make Safety Easy lets your crew acknowledge procedures on any device. Track who read what, when. No more lost paper forms.